Alarm Code 00
Status:
green
OK to Run
Description:
No Alarms Exist
Operator Action:
No action required.
-
Alarm Code 02
Status:
yellow
Check as Specified
Description:
Check Evaporator Coil Sensor (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 03
Status:
yellow
Check as Specified
Description:
Check (Control); Return Air Sensor (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 04
Status:
yellow
Check as Specified
Description:
Check (Control); Discharge Air Sensor (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 05
Status:
green
OK to Run
Description:
Check Ambient Temp Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 06
Status:
green
OK to Run
Description:
Check Coolant Temp Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 07
Status:
green
OK to Run
Description:
Check Engine RPM Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 08
Status:
yellow
Check as Specified
Description:
Unit Running on Coil Sensor (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code (09)
Status:
yellow
Check as Specified
Description:
High Evaporator Temperature (Zone)
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code (10)
Status:
red
Take Immediate Action
Description:
High Discharge Pressure (or Temperature)
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 11
Status:
yellow
Check as Specified
Description:
Unit or Zone Controlling on Alternate Sensor (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 12
Status:
red
Take Immediate Action
Description:
Sensor or Digital Input Shutdown (Zone)
Operator Action:
Unit/zone cannot operate and is shut down. Repair immediately.
-
Alarm Code 13
Status:
yellow
Check as Specified
Description:
Sensor Check (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 14
Status:
green
OK to Run
Description:
Defrost Terminated by Time
Operator Action:
Report alarm at end of day.
-
Alarm Code 15
Status:
yellow
Check as Specified
Description:
Check Glow Plugs or Intake Air Heater
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 16
Status:
green
OK to Run
Description:
Manual Start Not Completed
Operator Action:
Report alarm at end of day.
-
Alarm Code (17)
Status:
yellow
Check as Specified
Description:
Engine Failed to Crank
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code (18)
Status:
yellow
Check as Specified
Description:
High Engine Coolant Temperature
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code (19)
Status:
yellow
Check as Specified
Description:
Low Engine Oil Pressure
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code (20)
Status:
yellow
Check as Specified
Description:
Engine (Vapor Motor CR) Failed to Start
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code (21)
Status:
yellow
Check as Specified
Description:
Cooling Cycle Check (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code (22)
Status:
yellow
Check as Specified
Description:
Heating Cycle Check (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 23
Status:
red
Take Immediate Action
Description:
Cooling Cycle Fault (Zone)
Operator Action:
Unit/zone cannot operate and is shut down. Repair immediately.
-
Alarm Code 24
Status:
red
Take Immediate Action
Description:
Heating Cycle Fault (Zone)
Operator Action:
Unit/zone cannot operate and is shut down. Repair immediately.
-
Alarm Code 25
Status:
yellow
Check as Specified
Description:
Alternator Check
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code (26)
Status:
yellow
Check as Specified
Description:
Check Refrigeration Capacity (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code (27)
Status:
red
Take Immediate Action
Description:
Vapor Motor RPM High (CR)
Operator Action:
Unit cannot operate and is shut down. Repair immediately.
-
Alarm Code 28
Status:
green
OK to Run
Description:
Pretrip or Self Check Abort
Operator Action:
Report alarm at end of day.
-
Alarm Code 29
Status:
yellow
Check as Specified
Description:
Defrost Damper Circuit Check (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 30
Status:
red
Take Immediate Action
Description:
Defrost Damper Stuck Closed (Zone)
Operator Action:
Unit/zone cannot operate and is shut down. Repair immediately.
-
Alarm Code 31
Status:
yellow
Check as Specified
Description:
Check Oil Pressure Switch
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 32
Status:
red
Take Immediate Action
Description:
Refrigeration Capacity Low (Zone)
Operator Action:
Unit/zone cannot operate and is shut down. Repair immediately.
-
Alarm Code 33
Status:
green
OK to Run
Description:
Check Engine RPM
Operator Action:
Report alarm at end of day.
-
Alarm Code 34
Status:
yellow
Check as Specified
Description:
Check Modulation Circuit
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 35
Status:
red
Take Immediate Action
Description:
Check Run Relay Circuit
Operator Action:
Unit cannot operate and is shut down. Repair immediately.
-
Alarm Code (36)
Status:
red
Take Immediate Action
Description:
Electric Motor Failed to Run
Operator Action:
Unit cannot operate and is shut down. Repair immediately. Switch to Diesel Mode.
-
Alarm Code 37
Status:
green
OK to Run
Description:
Check Engine Coolant Level
Operator Action:
Report alarm at end of day.
-
Alarm Code 38
Status:
red
Take Immediate Action
Description:
Electric Phase Reversed
Operator Action:
If unit/zone is shut down repair immediately.
-
Alarm Code 39
Status:
yellow
Check as Specified
Description:
Check Water Valve Circuit
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 40
Status:
yellow
Check as Specified
Description:
Check High Speed Circuit
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 41
Status:
yellow
Check as Specified
Description:
Check Engine Coolant Temp
Operator Action:
Report alarm at end of day.
-
Alarm Code 42
Status:
yellow
Check as Specified
Description:
Unit Forced to Low Speed
Operator Action:
Report alarm at end of day.
-
Alarm Code 43
Status:
green
OK to Run
Description:
Unit Forced to Low Speed Modulation
Operator Action:
Report alarm at end of day.
-
Alarm Code 44
Status:
red
Take Immediate Action
Description:
Check Fuel System
Operator Action:
Add fuel as necessary. Otherwise, report alarm at end of day.
-
Alarm Code 45
Status:
yellow
Check as Specified
Description:
Check Hot Gas or Hot Gas Bypass Circuit
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 46
Status:
yellow
Check as Specified
Description:
Check Air Flow (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 47
Status:
red
Take Immediate Action
Description:
Remote Sensor Shutdown
Operator Action:
Unit/zone cannot operate and is shut down. Repair immediately.
-
Alarm Code 48
Status:
red
Take Immediate Action
Description:
Check Belts or Clutch
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 49
Status:
green
OK to Run
Description:
Check Spare Sensor 1
Operator Action:
Report alarm at end of day.
-
Alarm Code 50
Status:
green
OK to Run
Description:
Reset Clock
Operator Action:
Report alarm at end of day.
-
Alarm Code 51
Status:
red
Take Immediate Action
Description:
Check Shutdown Circuit
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 52
Status:
yellow
Check as Specified
Description:
Check Heat Circuit (Zone)
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 53
Status:
yellow
Check as Specified
Description:
Check Economizer Valve Circuit
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 54
Status:
green
OK to Run
Description:
Test Mode Timeout
Operator Action:
Clear alarm and restart unit.
-
Alarm Code 55
Status:
green
OK to Run
Description:
Check Engine Speeds
Operator Action:
Report alarm at end of day.
-
Alarm Code 56
Status:
yellow
Check as Specified
Description:
Check Evaporator Fan Low Speed (Zone)
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 57
Status:
yellow
Check as Specified
Description:
Check Evaporator Fan High Speed (Zone)
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 61
Status:
yellow
Check as Specified
Description:
Low Battery Voltage
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 62
Status:
red
Take Immediate Action
Description:
Ammeter Out of Calibration
Operator Action:
Unit cannot operate and is shut down. Repair immediately.
-
Alarm Code (63)
Status:
red
Take Immediate Action
Description:
Engine or Vapor Motor Stopped
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 64
Status:
green
OK to Run
Description:
Pretrip Reminder
Operator Action:
Report alarm at end of day.
-
Alarm Code 65
Status:
yellow
Check as Specified
Description:
Abnormal Temperature Differential (Zone)
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 66
Status:
red
Take Immediate Action
Description:
Low Engine Oil Level
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 67
Status:
yellow
Check as Specified
Description:
Check Liquid Line Solenoid Circuit (Zone)
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 68
Status:
red
Take Immediate Action
Description:
Internal Controller Fault Code
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 70
Status:
green
OK to Run
Description:
Hourmeter Failure
Operator Action:
Report alarm at end of day.
-
Alarm Code 71
Status:
green
OK to Run
Description:
Hourmeter 4 Exceeds Set Time Limit
Operator Action:
Report alarm at end of day.
-
Alarm Code 72
Status:
green
OK to Run
Description:
Hourmeter 5 Exceeds Set Time Limit
Operator Action:
Report alarm at end of day.
-
Alarm Code 73
Status:
green
OK to Run
Description:
Hourmeter 6 Exceeds Set Time Limit
Operator Action:
Report alarm at end of day.
-
Alarm Code 74
Status:
green
OK to Run
Description:
Controller Reset to Defaults
Operator Action:
Report alarm at end of day.
-
Alarm Code 75
Status:
red
Take Immediate Action
Description:
Controller RAM Failure
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 76
Status:
red
Take Immediate Action
Description:
Controller EPROM Failure
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 77
Status:
red
Take Immediate Action
Description:
Controller EPROM Checksum Failure
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 78
Status:
red
Take Immediate Action
Description:
Data Log EPROM Failure
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 79
Status:
green
OK to Run
Description:
Internal Data Logger Overflow
Operator Action:
Report alarm at end of day.
-
Alarm Code 80
Status:
green
OK to Run
Description:
Check Compressor Temp Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 81
Status:
red
Take Immediate Action
Description:
High Compressor Temp
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 82
Status:
red
Take Immediate Action
Description:
High Compressor Temp Shutdown
Operator Action:
Unit cannot operate and is shut down. Repair immediately.
-
Alarm Code 83
Status:
green
OK to Run
Description:
Low Engine Coolant Temp
Operator Action:
Report alarm at end of day.
-
Alarm Code 84
Status:
green
OK to Run
Description:
Restart Null
Operator Action:
Report alarm at end of day.
-
Alarm Code 85
Status:
green
OK to Run
Description:
Forced Unit Operation
Operator Action:
Report alarm at end of day.
-
Alarm Code 86
Status:
green
OK to Run
Description:
Check Discharge Pressure Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 87
Status:
green
OK to Run
Description:
Check Suction Pressure Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 88
Status:
green
OK to Run
Description:
Reserved for CR
Operator Action:
-
Alarm Code 89
Status:
green
OK to Run
Description:
Check Electronic Throttling Valve (ETV) Circuit
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 90
Status:
green
OK to Run
Description:
Electric Overload
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 91
Status:
green
OK to Run
Description:
Check Electric Ready Input
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 92
Status:
green
OK to Run
Description:
Sensor Grades Not Set (Zone)
Operator Action:
Report alarm at end of day.
-
Alarm Code 93
Status:
green
OK to Run
Description:
Low Compressor Suction Pressure
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 94
Status:
green
OK to Run
Description:
Check Loader #1 Circuit
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 95
Status:
green
OK to Run
Description:
Check Loader #2 Circuit
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 96
Status:
yellow
Check as Specified
Description:
Low Fuel Level
Operator Action:
Add fuel as required.
-
Alarm Code 97
Status:
red
Take Immediate Action
Description:
Failed Remote Return Air Sensor (CR)
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 98
Status:
green
OK to Run
Description:
Check Fuel Level Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 99
Status:
red
Take Immediate Action
Description:
High Compressor Pressure Ratio
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code (100)
Status:
yellow
Check as Specified
Description:
Heater Fan Failure (CR)
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 101
Status:
red
Take Immediate Action
Description:
Controlling on Evap Coil Outlet Temp (CR)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code (102)
Status:
yellow
Check as Specified
Description:
Low Evaporator Coil Temperature (CR)
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 103
Status:
yellow
Check as Specified
Description:
Low Heater Fuel Level (CR)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 104
Status:
yellow
Check as Specified
Description:
Check Remote Fan Speed (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 105
Status:
yellow
Check as Specified
Description:
Check Receiver Tank Press Sol Circuit
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 106
Status:
yellow
Check as Specified
Description:
Check Purge Valve Circuit
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 107
Status:
yellow
Check as Specified
Description:
Check Condenser Inlet Sol Circuit
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 108
Status:
yellow
Check as Specified
Description:
Door Open Timeout (Zone)
Operator Action:
Close doors. Report alarm at end of day.
-
Alarm Code 110
Status:
yellow
Check as Specified
Description:
Check Suction Line Sol Circuit (Zone)
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 111
Status:
green
OK to Run
Description:
Unit Not Configured Correctly (Zone)
Operator Action:
Report alarm at end of day.
-
Alarm Code 112
Status:
yellow
Check as Specified
Description:
Check Remote Fans (Zone)
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 113
Status:
yellow
Check as Specified
Description:
Check Electric Heat Circuit (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 114
Status:
red
Take Immediate Action
Description:
Multiple Alarms - Can Not Run (Zone)
Operator Action:
Unit/zone cannot operate and is shut down. Repair immediately.
-
Alarm Code 115
Status:
yellow
Check as Specified
Description:
Check High Pressure Cut Out Switch
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 116
Status:
green
OK to Run
Description:
Check High Pressure Cut In Switch
Operator Action:
Report alarm at end of day.
-
Alarm Code 117
Status:
green
OK to Run
Description:
Auto Switch from Diesel to Electric
Operator Action:
Normal operation – does not affect performance.
-
Alarm Code 118
Status:
green
OK to Run
Description:
Auto Switch from Electric to Diesel
Operator Action:
Normal operation – does not affect performance.
-
Alarm Code 120
Status:
yellow
Check as Specified
Description:
Check Alternator Excite Circuit
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 121
Status:
yellow
Check as Specified
Description:
Check PMW Liquid Injection Circuit
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 122
Status:
yellow
Check as Specified
Description:
Check Diesel/Electric Circuit
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 123
Status:
yellow
Check as Specified
Description:
Check Evap Coil Inlet Temp Sensor (CR)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 124
Status:
green
OK to Run
Description:
Check Evap Coil Outlet Temp Sensor (CR)
Operator Action:
Report alarm at end of day.
-
Alarm Code 125
Status:
yellow
Check as Specified
Description:
Check Tank Level Sensor (CR)
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 126
Status:
yellow
Check as Specified
Description:
Check Back Pressure Regulator (CR)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 127
Status:
yellow
Check as Specified
Description:
Setpoint Not Entered (Zone)
Operator Action:
Be sure setpoint is adjusted to required temperature.
-
Alarm Code 128
Status:
green
OK to Run
Description:
Engine Run Time Maint Reminder #1/Service Due
Operator Action:
Report alarm at end of day.
-
Alarm Code 129
Status:
green
OK to Run
Description:
Engine Run Time Maint Reminder #2
Operator Action:
Report alarm at end of day.
-
Alarm Code 130
Status:
green
OK to Run
Description:
Engine Run Time Maint Reminder #1
Operator Action:
Report alarm at end of day.
-
Alarm Code 131
Status:
green
OK to Run
Description:
Electric Run Time Maint Reminder #2
Operator Action:
Report alarm at end of day.
-
Alarm Code 132
Status:
green
OK to Run
Description:
Total Unit Run Time Maint Reminder #1
Operator Action:
Report alarm at end of day.
-
Alarm Code 133
Status:
green
OK to Run
Description:
Total Unit Run Time Maint Reminder #2
Operator Action:
Report alarm at end of day.
-
Alarm Code 134
Status:
green
OK to Run
Description:
Controller Power On Hours
Operator Action:
Report alarm at end of day.
-
Alarm Code 135
Status:
green
OK to Run
Description:
Check Spare Digital Inputs
Operator Action:
Report alarm at end of day.
-
Alarm Code 137
Status:
green
OK to Run
Description:
Check Spare Digital Outputs
Operator Action:
Report alarm at end of day.
-
Alarm Code 137
Status:
yellow
Check as Specified
Description:
Check Damper Motor Heater Output
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 138
Status:
green
OK to Run
Description:
Log DAS Real Time Clock Battery Failure (DAS)
Operator Action:
Report alarm at end of day.
-
Alarm Code 139
Status:
green
OK to Run
Description:
Abort Evacuation Mode
Operator Action:
Report alarm at end of day.
-
Alarm Code 141
Status:
yellow
Check as Specified
Description:
Auto Switch Diesel to Electric Disabled
Operator Action:
Report alarm at end of day.
-
Alarm Code 142
Status:
yellow
Check as Specified
Description:
Check Thermax Valve
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 143
Status:
green
OK to Run
Description:
Check Remote Drain Hose Heater Output (Zone)
Operator Action:
Report alarm at end of day.
-
Alarm Code 144
Status:
red
Take Immediate Action
Description:
Lost CAN Communications to Expansion Module
Operator Action:
Unit cannot operate and is shut down. Repair immediately.
-
Alarm Code 145
Status:
yellow
Check as Specified
Description:
Lost Controller ON Feedback Signal
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 146
Status:
green
OK to Run
Description:
Software Version Mismatch
Operator Action:
Report alarm at end of day.
-
Alarm Code 147
Status:
yellow
Check as Specified
Description:
Check Multi-Temp Fan Speed Control Output (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 148
Status:
yellow
Check as Specified
Description:
Auto Switch Electric to Diesel Disabled
Operator Action:
Report alarm at end of day.
-
Alarm Code 149
Status:
yellow
Check as Specified
Description:
Alarm Not Identified
Operator Action:
If unit/zone is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 150
Status:
green
OK to Run
Description:
Sensor Out of Range Low (DAS and HMI) (Zone)
Operator Action:
Report alarm at end of day.
-
Alarm Code 151
Status:
green
OK to Run
Description:
Sensor Out of Range High (DAS and HMI) (Zone)
Operator Action:
Report alarm at end of day.
-
Alarm Code 152
Status:
green
OK to Run
Description:
DAS Failed Sensor (DAS)
Operator Action:
Report alarm at end of day.
-
Alarm Code 153
Status:
green
OK to Run
Description:
Expansion Module Flash Load Failure
Operator Action:
Report alarm at end of day.
-
Alarm Code 154
Status:
yellow
Check as Specified
Description:
Low Suction Pressure Switch Failure
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 155
Status:
red
Take Immediate Action
Description:
Lost CAN Communications to HMI
Operator Action:
Unit cannot operate and is shut down. Repair immediately.
-
Alarm Code 156
Status:
yellow
Check as Specified
Description:
Check Suction/Liquid Heat Exchanger Bypass Valve
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 157
Status:
green
OK to Run
Description:
OptiSet Plus Profile Mismatch
Operator Action:
Report alarm at end of day.
-
Alarm Code 158
Status:
green
OK to Run
Description:
Primary Software Failed to Load
Operator Action:
Report alarm at end of day.
-
Alarm Code 159
Status:
green
OK to Run
Description:
Check Battery Condition
Operator Action:
Report alarm at end of day.
-
Alarm Code 160
Status:
green
OK to Run
Description:
Lost CAN Communications to Radio Expansion Board
Operator Action:
Report alarm at end of day.
-
Alarm Code 161
Status:
green
OK to Run
Description:
Log DAS Real Time Clock Invalid (DAS)
Operator Action:
Report alarm at end of day.
-
Alarm Code 163
Status:
yellow
Check as Specified
Description:
Emission Control Failure
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 175
Status:
yellow
Check as Specified
Description:
Check Electronic Expansion Valve (CR)
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 176
Status:
yellow
Check as Specified
Description:
Check Evaporator Pressure Sensor (CR)
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 177
Status:
yellow
Check as Specified
Description:
Check CO2 Tank Pressure Sensor (CR)
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 178
Status:
yellow
Check as Specified
Description:
Low CO2 Fuel Level (CR)
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 180
Status:
yellow
Check as Specified
Description:
TriPac Compressor Alarm
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 188
Status:
yellow
Check as Specified
Description:
Log DAS Microprocessor Fault (DAS)
Operator Action:
Report alarm at end of day.
-
Alarm Code 203
Status:
yellow
Check as Specified
Description:
Check Display Return Air Sensor (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 204
Status:
yellow
Check as Specified
Description:
Check Display Discharge Air Sensor (Zone)
Operator Action:
Manually monitor temperature. Report alarm at end of day.
-
Alarm Code 216
Status:
green
OK to Run
Description:
Check DAS Digital Inputs (DAS)
Operator Action:
Report alarm at end of day.
-
Alarm Code 233
Status:
green
OK to Run
Description:
REB Switching Off, Conservative to Full Null
Operator Action:
Report alarm at end of day.
-
Alarm Code 234
Status:
green
OK to Run
Description:
Check Relative Humidity Sensor Circuit
Operator Action:
Report alarm at end of day.
-
Alarm Code 235
Status:
green
OK to Run
Description:
High Engine Coolant Temperature Check
Operator Action:
Report alarm at end of day.
-
Alarm Code 250
Status:
green
OK to Run
Description:
DAS Clock Time Reset (DAS)
Operator Action:
Report alarm at end of day.
-
Alarm Code 251
Status:
green
OK to Run
Description:
Check Radio Expansion Board Configuration
Operator Action:
Report alarm at end of day.
-
Alarm Code 252
Status:
green
OK to Run
Description:
Check Auto Fresh Air Exchange Circuit
Operator Action:
Report alarm at end of day.
-
Alarm Code 253
Status:
green
OK to Run
Description:
REB On Back Up Battery, Alarms Disabled
Operator Action:
Report alarm at end of day.
-
Alarm Code 254
Status:
green
OK to Run
Description:
Check Auxiliary Coolant Temp Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 500
Status:
yellow
Check as Specified
Description:
Check Host Evaporator Blower Low Speed
Operator Action:
Not implemented
-
Alarm Code 501
Status:
yellow
Check as Specified
Description:
Check Host Evaporator Blower High Speed
Operator Action:
Not implemented
-
Alarm Code 505
Status:
yellow
Check as Specified
Description:
Check Roadside Condenser Fan Motor Speed Circuit
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 506
Status:
yellow
Check as Specified
Description:
Check Curbside Condenser Fan Motor Speed Circuit
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 507
Status:
green
OK to Run
Description:
Check Digital Scroll Output Circuit (Scroll Only)
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 508
Status:
green
OK to Run
Description:
Speed Request Communication Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 509
Status:
yellow
Check as Specified
Description:
ECU Failed to Enable
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 510
Status:
yellow
Check as Specified
Description:
ECU Run Signal Failed
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 511
Status:
green
OK to Run
Description:
Engine Wait to Start Time Delay Expired
Operator Action:
Report alarm at end of day.
-
Alarm Code 512
Status:
yellow
Check as Specified
Description:
High Compressor Suction Pressure (Scroll Only)
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 513
Status:
yellow
Check as Specified
Description:
Low Compressor Suction Ratio (Scroll Only)
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 514
Status:
yellow
Check as Specified
Description:
Low Compressor Discharge Pressure (Scroll Only)
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 515
Status:
yellow
Check as Specified
Description:
Minimum ETV Discharge Superheat Temp (Scroll)
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 516
Status:
red
Take Immediate Action
Description:
I/O Controller to Application Controller Com Failure
Operator Action:
The unit is no longer able to operate and has been shut down. Repair immediately.
-
Alarm Code 518
Status:
yellow
Check as Specified
Description:
Generator Ground Fault
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 519
Status:
yellow
Check as Specified
Description:
Check Battery Charger Input Power
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 520
Status:
yellow
Check as Specified
Description:
Check Battery Charger Output Power
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 521
Status:
yellow
Check as Specified
Description:
Battery Charger External/Environmental Fault
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 522
Status:
yellow
Check as Specified
Description:
Battery Temperature Sensor Alarm
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 523
Status:
yellow
Check as Specified
Description:
Battery Charger Indicated Conditions
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 524
Status:
yellow
Check as Specified
Description:
Generator Op Limit Vout to Frequency Ration
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 525
Status:
yellow
Check as Specified
Description:
Generator Frequency Range Fault
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 526
Status:
yellow
Check as Specified
Description:
Generator Operational Limit Output Current
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 528
Status:
yellow
Check as Specified
Description:
Failed J1939 CAN Comm Base Controller/Charger
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 529
Status:
yellow
Check as Specified
Description:
Check Fuel Pump Circuit
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 530
Status:
yellow
Check as Specified
Description:
Low Pressure Differential (Scroll only)
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 531
Status:
yellow
Check as Specified
Description:
Check Economizer Pressure Sensor (Scroll only)
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 538
Status:
yellow
Check as Specified
Description:
Engine J1939 CAN Data Link Degraded
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 539
Status:
yellow
Check as Specified
Description:
Engine J1939 CAN Data Link Failed
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 540
Status:
yellow
Check as Specified
Description:
Illegal Engine Operating State
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 542
Status:
green
OK to Run
Description:
Battery Charger Fault – Unit Forced to Low Speed
Operator Action:
Maintenance information only. Report alarm at end of day.
-
Alarm Code 543
Status:
green
OK to Run
Description:
Battery Charger Internal Short
Operator Action:
Maintenance information only. Report alarm at end of day.
-
Alarm Code 544
Status:
green
OK to Run
Description:
Battery Charger External Short
Operator Action:
Maintenance information only. Report alarm at end of day.
-
Alarm Code 545
Status:
green
OK to Run
Description:
Battery Charger Output Voltage Exceeded Limit
Operator Action:
Maintenance information only. Report alarm at end of day.
-
Alarm Code 546
Status:
green
OK to Run
Description:
Battery Charger Operating Bulk Voltage Out of Range
Operator Action:
Maintenance information only. Report alarm at end of day.
-
Alarm Code 547
Status:
yellow
Check as Specified
Description:
AC Bus Phase Loss
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 548
Status:
green
OK to Run
Description:
Battery Charger Temperature Below Operating Range
Operator Action:
Maintenance information only. Report alarm at end of day.
-
Alarm Code 549
Status:
green
OK to Run
Description:
Battery Charger AC Input Overvoltage
Operator Action:
Maintenance information only. Report alarm at end of day.
-
Alarm Code 550
Status:
yellow
Check as Specified
Description:
Battery Charger Internal Overvoltage Fault
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 551
Status:
green
OK to Run
Description:
Battery Charger Internal Temp Sensor Fault
Operator Action:
-
Alarm Code 552
Status:
green
OK to Run
Description:
Battery Charger Charging – Low Battery
Operator Action:
-
Alarm Code 553
Status:
green
OK to Run
Description:
Battery Charger Operating Derated Due to High temp
Operator Action:
-
Alarm Code 599
Status:
green
OK to Run
Description:
Engine Service Tool Connected
Operator Action:
Report alarm at end of day.
-
Alarm Code 600
Status:
green
OK to Run
Description:
Check Crankshaft Speed Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 601
Status:
green
OK to Run
Description:
Check Camshaft Speed Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 603
Status:
green
OK to Run
Description:
Check Exhaust Pressure Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 604
Status:
green
OK to Run
Description:
Check Coolant Temp Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 605
Status:
green
OK to Run
Description:
Check Fresh Air Temp Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 607
Status:
green
OK to Run
Description:
Check Fuel Temperature Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 608
Status:
green
OK to Run
Description:
Check Rail Pressure Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 609
Status:
green
OK to Run
Description:
Check Intake Pressure Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 610
Status:
green
OK to Run
Description:
Check Atmospheric Pressure Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 611
Status:
green
OK to Run
Description:
Check Glow Plug Circuit
Operator Action:
Report alarm at end of day.
-
Alarm Code 613
Status:
green
OK to Run
Description:
Check Injectors
Operator Action:
Report alarm at end of day.
-
Alarm Code 614
Status:
green
OK to Run
Description:
Check High Pressure Fuel Pump
Operator Action:
Report alarm at end of day.
-
Alarm Code 615
Status:
yellow
Check as Specified
Description:
Rail Pressure Fault
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 616
Status:
yellow
Check as Specified
Description:
Engine Overspeed
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 617
Status:
yellow
Check as Specified
Description:
Internal ECU Fault
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 618
Status:
green
OK to Run
Description:
Check EGR System
Operator Action:
Report alarm at end of day.
-
Alarm Code 619
Status:
green
OK to Run
Description:
ECU Main Relay Fault
Operator Action:
Report alarm at end of day.
-
Alarm Code 620
Status:
yellow
Check as Specified
Description:
No RPM Detected During Start Attempt
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 623
Status:
green
OK to Run
Description:
TRUCAN Message Timeout
Operator Action:
Report alarm at end of day.
-
Alarm Code 624
Status:
green
OK to Run
Description:
Check EGR Temperature Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 625
Status:
green
OK to Run
Description:
Check Intake Air Temperature Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 626
Status:
green
OK to Run
Description:
Check Exhaust Temperature Sensor
Operator Action:
Report alarm at end of day.
-
Alarm Code 642
Status:
green
OK to Run
Description:
ECU Forced Low Speed
Operator Action:
Report alarm at end of day.
-
Alarm Code 699
Status:
yellow
Check as Specified
Description:
Unknown ECU Fault
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 800
Status:
green
OK to Run
Description:
Crankshaft Position Sensor Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 801
Status:
green
OK to Run
Description:
Camshaft Position Sensor Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 804
Status:
green
OK to Run
Description:
Engine Coolant Temperature Sensor Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 807
Status:
green
OK to Run
Description:
Fuel Temperature Sensor Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 808
Status:
green
OK to Run
Description:
Rail Pressure Sensor Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 809
Status:
green
OK to Run
Description:
Intake Air Pressure Sensor Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 810
Status:
green
OK to Run
Description:
Atmospheric Pressure Sensor Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 811
Status:
green
OK to Run
Description:
Glow Plug Circuit Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 813
Status:
green
OK to Run
Description:
General Injector Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 815
Status:
yellow
Check as Specified
Description:
Fuel Pressure Regulator Error
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 818
Status:
green
OK to Run
Description:
EGR Valve Actuator Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 819
Status:
green
OK to Run
Description:
ECU Power Relay Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 825
Status:
green
OK to Run
Description:
T1 Air Intake Temperature Sensor Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 826
Status:
green
OK to Run
Description:
T2 Air Intake Temperature Sensor Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 827
Status:
green
OK to Run
Description:
EGR Valve Position Sensor Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 828
Status:
green
OK to Run
Description:
Lambda System Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 829
Status:
green
OK to Run
Description:
Main ECU Relay Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 829
Status:
green
OK to Run
Description:
Engine Communication Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 830
Status:
green
OK to Run
Description:
Air Flow Meter Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 832
Status:
green
OK to Run
Description:
Engine Power Supply Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 833
Status:
green
OK to Run
Description:
High Pressure Pump Fuel Metering Unit Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 834
Status:
green
OK to Run
Description:
Water in Fuel Sensor Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 836
Status:
green
OK to Run
Description:
Major ECU Failures
Operator Action:
Report alarm at end of day.
-
Alarm Code 838
Status:
green
OK to Run
Description:
Intake Air System Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 839
Status:
green
OK to Run
Description:
Engine Speed Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 840
Status:
green
OK to Run
Description:
Fuel Injection Energizing Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 841
Status:
green
OK to Run
Description:
High Pressure Pump Wear
Operator Action:
Report alarm at end of day.
-
Alarm Code 842
Status:
green
OK to Run
Description:
Engine Running in Safe Mode – Low Speed
Operator Action:
Report alarm at end of day.
-
Alarm Code 843
Status:
green
OK to Run
Description:
Fuel Injection System Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 844
Status:
green
OK to Run
Description:
Engine Failed to Crank
Operator Action:
Report alarm at end of day.
-
Alarm Code 845
Status:
green
OK to Run
Description:
Starter Relay Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 846
Status:
green
OK to Run
Description:
T50 Switch Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 847
Status:
green
OK to Run
Description:
Variant Coding Error
Operator Action:
Report alarm at end of day.
-
Alarm Code 853
Status:
yellow
Check as Specified
Description:
Engine Overspeed (No DTC)
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 854
Status:
yellow
Check as Specified
Description:
Engine Protection Self Shutdown
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code 899
Status:
yellow
Check as Specified
Description:
Unknown ECU Fault
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code SOF
Status:
red
Take Immediate Action
Description:
Microprocessor Software Failure
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code tEP
Status:
red
Take Immediate Action
Description:
Electric Standby Motor Thermal Protection Alarm
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code - C -
Status:
red
Take Immediate Action
Description:
Communications Failure, Microprocessor to In-Cab Control Box
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code dr2
Status:
yellow
Check as Specified
Description:
Door 2 Open/Door Switch 2 Failure
Operator Action:
Close door. Report alarm at end of day.
-
Alarm Code LP
Status:
red
Take Immediate Action
Description:
Low Suction Pressure
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code P1E
Status:
yellow
Check as Specified
Description:
Return Air Temperature Sensor Fault
Operator Action:
Report alarm at end of day.
-
Alarm Code HP
Status:
red
Take Immediate Action
Description:
High Discharge Pressure
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code dr1
Status:
yellow
Check as Specified
Description:
Door 1 Open/Door Switch 1 Failure
Operator Action:
Close door. Report alarm at end of day.
-
Alarm Code OL
Status:
red
Take Immediate Action
Description:
Electric Standby Overload
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code P2E
Status:
yellow
Check as Specified
Description:
Remote Return Air Temperature Sensor Fault
Operator Action:
Report alarm at end of day.
-
Alarm Code bAt
Status:
red
Take Immediate Action
Description:
Low Battery Voltage
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code tP4
Status:
red
Take Immediate Action
Description:
Power Supply Thermal Protection Alarm
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code PSE
Status:
red
Take Immediate Action
Description:
High Pressure Sensor Fault
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.
-
Alarm Code tCO
Status:
red
Take Immediate Action
Description:
Electronic Control Module Internal Temperature Exceeds Limit
Operator Action:
If unit is shut down repair immediately. Otherwise, report alarm at end of day.